    pH, Conductivity and Ionselectiv Measurements

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se2

    Hach sensION+ portable meters are compact, rugged lightweight, and ideally suited for field measurements.

    Portable Meters Hach sensION+

    SensION+ Portable Meters

    Waterproof IP67, shock resistant housing Large backlit graphic screen with icon navigation Simultaneous display of various parameters Combined electrodes with built-in temperature probe and watertight connector Carrying case designed to be a portable laboratory!

    SensION+ portable meters, technical specifications

    PORTABLE METERS

    Measuring rangespH: -2.00 to 19.99mV: +/- 1400Conductivity: 0.01S/cm to 500 ms/cmTDS: 0 mg/l to 500 g/lSalinity: 0 to 50 g/l NaClDissolved OxygenSaturation: 0 to 250 % (25C)Concentration 0 to 22 mg/l (25C)Temperature: -20 to 150C (0 to 50C for DO)Temperature compensationAutomatic thanks to the Pt 1000 built-in in theprobes.Temperature correction for conductivityLinear correction factor from 0 to 9,99 %/C(default value 2 %)Reference temperature 20 or 25CTDS conversion factor0 to 4,44 (default value 0,64)Measuring modeUpon stabilisation or continuous

    CalibrationpH1,2 or 3 calibration pointsAutomatic recognition of buffer solutionspH 2,00/4,01 /7,00 and 10,00 at 25CManual calibration using the buffer solution of your choiceRestore factory calibration optionmVAutomatic recognition of a standard solution 220 mV at 25CManual calibration using the standard solution ofyour choiceRestore factory calibration optionConductivity1,2 or 3 calibration pointsStored calibration solutions 147 S/cm, 1413S/cm, 12,88 mS/cm and 111,8 mS/cm at 25CManual calibration using the standard solution ofyour choiceRestore factory calibration optionDissolved Oxygen1 or 2 calibration pointsManual calibration at 0 and 100 % saturationTemperature adjustmentDrift correction of the temperature probe at 25 and 85C

    DisplayLCD with backlightSimultaneous display of several parametersIcon navigationPower supply3 x AA batteries, battery life depends on model,above 500 hours for pH-meterAutomatic switch off after 5 min. (this function can be disabled)ConnectionWatertight electrode connector MP-5 (5 contacts) for PH1 / EC5MP-8 (8 contacts) for MM150Meter housing featuresABS, waterproof IP67Dimensions 186 x 73 x38mmWeight 300 gWorking environmentWorking T: 0 to 50CStorage T: -15 to 65CRelative humidity rate

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    3

    Electrodes for SensION+ Portable Meters

    Specifications Combined pH General use Combined pH waste water

    Combined pH Low conductivity high temperature

    Combined pH puncture type

    Combined pH puncture type

    Model 5050T 5051T 5052T 5053T 5054T

    Special feature Gel With working protector open junctionWith working protector

    PTFE junctionBuilt-in T probe 2

    junctionsRemovable steel knife,Built-in T

    Measuring range 0 to 14 pH 2 to 14 pH 0 to 14 pH 2 to 14 pH 2 to 14 pHTemperature range 0 to 80 C 0 to 80 C 0 to 100 C 0 to 60 C 0 to 60 CTemperature probe Pt1000 Pt1000 Pt1000 Pt1000 Pt1000Dimensions (under head) 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mmSensitive component Glass Glass Glass Glass GlassBody material Polycarbonate Glass Glass Stainless steel Stainless steelFilling Gel Solid Gel Solid SolidConnector MP-5 MP-5 MP-5 MP-5 MP-5Cable length 1 m 1 m 1 m 1 m 1 mProduct number LZW5050T.97.002 LZW5051T.97.002 LZW5052T.97.002 CRI5053T.99 CRI5054TC.99

    PORTABLE METERS

    Specifications Conductivity General useConductivity Difficult

    samples Multi* Multi*

    Model 5060 5062 5048 5059 Special feature - Rugged titanium body pH/Conductivity/ORP pH/Conductivity

    Measuring range 0,2 S/cm up to 200 mS/cm 5 S/cm up to 50 mS/cm0 to 14 pH

    25-200 mS/cm +/- 2000 mV

    0 to 14 pH 5 S/cm to 30 mS/cm

    +/- 2000 mVTemperature range 0 to 80 C 0 to 80 C 0 to 80 C 0 to 80 C Temperature probe Pt1000 Pt1000 Pt1000 Pt1000 Dimensions (under head) 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm

    Sensitive component Platinum Platinum pH: Glass Cond & Redox: PlatinumpH: Glass

    Cond: Titanium

    Body material Polycarbonate Titanium Polycarbonate Polycarbonate Filling - - Gel Gel Connector MP-5 MP-5 MP-8 MP-8 Cable length 1 m 1 m 1 m 1 m Product number LZW5060.97.0002 LZW5062.97.0002 LZW5048.97.0002 LZW5059.97.0002

    *Only compatible with sensION+ multimeter MM150

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se4

    Hach sensION+ Benchtop Meters are designed to be all-in-one working stations, ready for a widevariety of applications, and come complete withintegrated electrode holder and magnetic stirrer.

    Benchtop Meters Hach sensION+

    SensION+ Benchtop Meters

    Housing and keyboard splashproof IP42 Large graphic display with backlight Electrode parking positions Colour coded calibration flasks with magnetic rod Electrode holder fitted with a safe cable fastener Built-in magnetic stirrer controlled from the instrument

    BENCHTOP METERS

    Parameters PH3

    Benchtop pH-meter

    PH31 GLP Benchtop

    pH-meter

    EC7 Benchtop

    conductivity meter

    EC71 GPL Benchtop

    conductivity meter

    MM374 GLP Benchtop multimeter

    Temperature x x x x xpH x x xConductivity x x xResistivity x xSalinity x x xTDS x xORP/Redox x x xNitrates xFluoride xSodium xChloride xAmmonium xAmmonia xSpecificationsNo of measuring channels 1 1 1 1 2GLP functions x x xPC or printer output x x xProduct number LPV2000.98.0002 LPV2100.98.0002 LPV3010.98.0002 LPV3110.98.000 LPV4110.98.0002

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    5

    SensION+ benchtop meters, technical specificationsMeasuring rangespH: -2.00 to 19.99mV: +/- 2000Conductivity: 0,01/0.001*S/cm up to 500/1000** ms/cm(*with Constant=0,1 cm-1, **with Constant=10 cm-1)Resistivity: 0 to 100 MOhmsTDS: 0 mg/l to 500 g/lSalinity: 5,85 mg/l to 311,1g/l NaClISE: 10-5 M to 10-1 MTemperature: -20 to 150CTemperature compensationAutomatic with Pt 1000 or 10 kOhms temperatureprobeManual if no T sensor connected.Temperature correction for conductivityLinear correction factor from 0 to 9,99%/C (default value 2%)Correction factor for natural waters following UNEEN 27888 Except EC7Reference temperature 20 or 25CTDS conversion factor0 to 4,44 (default value 0,64)CalibrationAdjustable calibration alarmAutomatic rejection of electrodes in poor conditionpH1,2 or 3 calibration points

    Automatic recognition of buffers among following series: pH 2,00/4,01/7,00 and 10,00 at 25C) pH 1,679/4,006/6,865/7,00/9,18/10,012/12,454 at 25C - Except PH3Series of 3 free selectable buffer values - Except PH3Manual calibration using any value -Except PH3Manual entry of calibration results - Except PH3Restore factory calibration option mVAutomatic recognition of a standard 220 mV at 25CManual calibration using any value - Except PH3Manual entry of calibration values - Except PH3Restore factory calibration option - Except PH3Conductivity1, 2 or 3 calibration pointsSelection of standards in the following series Molar 147 S/cm, 1413 S/cm, 12,88 mS/cm,111,8 mS/cm at 25C Demal 1049 S/cm, 12,85 mS/cm, 111,31 mS/cm at 25C Except EC7 NaCl 1014,9 S/cm for salinityManual calibration using any value Except EC7Manual entry of the cell constantRestore factory calibration optionIonmetry (ISE)2 to 5 calibration pointsSeries of 5 users selectable calibration solutionsStorage of 4 calibration curves

    Temperature adjustmentDrift correction of the temperature probe at 25 and 85C - Except PH3 and EC7Measuring modeUpon stabilisation, continuous or by time - ExceptPH3 and EC72 independant measuring channels for MM340 and MM374GLP functions Except PH3 and EC7340 results stored for each channel and 9 calibrationresultsDate/Time, sample ID, user IDConnectionsCombined/indicator electrode: BNCReference electrode: banana 5 mmConductivity cell: 8 contact telephone plugT: 5 mm banana or 4 contact telephone plugData transfer Except PH3 and EC7RS232 output for PC or printerRS232 USB adapter as optionDisplayLCD graphic with backlightMenu available in French, English, Spanish, German, PortuguesePower supplyMains adapter 100-240 VAC (0,4 A/47-63 Hz)

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se6

    ElectrodesMaintenance

    Electrode

    Visually inspect the electrode. If there are bubbles in the bottom of the electrode, spin the electrode around by holding the cord. This will push the liquid into the lower part of the electrode rod.Control the crystal level in the electrode. If too high: liquid in the electrode should be emptied, the crystals rinsed with distilled water and the electrode refilled with fresh KCl solution. If too low: fill with saturated KCl or fresh KCl crystals.Clean the electrode regularly with Renovo N (Renovo x if fat samples are measured). To ensure accurate results avoid contact with the bottom of the cup during measurement. Keep the electrode in pH 4 buffer overnight (not colored). Please note that this will lead to higher dissolving of the crystals.Rinse electrode with distilled water between samples. If an electrode is stored in KCl (new electrode), it must be soaked in buffer pH 4 for at least 2 hours before use. Check the electrodes instructions as storage and activation recommendations may differ between electrodes.

    Conductivity Cell

    Clean platinum-coated conductivity cells gently, aggressive cleaning may lead to degradation of the platinum surface layer.Rinse the cell with deionized water between sample measurements. If fat samples have been measured, the cell can first be cleaned with solvents that dissolve the sample (for example ethanol and acetone). Finish by washing the cell with water.If deposits occur on the cell surface, it can be dipped in Renovo N (cleaning kit from Radiometer) for 1h and then be cleaned with deionized water.For short-term storage, the cell can be stored in deionized water. For long-term storage, the cell can be kept dry, or placed in deionized water. After long-term storage, the electrode needs to be placed in deionized water for 8 hours before use.Do not touch the shiny surface of the platinum-coated cells. To clean the platinum cells, dip the cell in deionized water several times. Do not rinse it with excessive water pressure. The pressure may lead to a part of the platinum layer being rinsed off, this will affect the cell-constant and lead to incorrect measurement results.

    MAINTENANCE

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    7

    Radiometer Analyticals unique Red Rod Technology providesnot only fast response time but also long-term accuracy andreproducibility.

    Red Rod ElectrodesRadiometer Analytical - Hach Lange

    Features:

    Reproducible measuring conditions ensured by the special bayonet head. The electrode fits into place in one easy movement and is fixed safely and securely in the same position for every measurement.

    Wide temperature range (0 to 100C) thanks to fast temperature response of Red Rod Technology.

    Trouble-free liquid junction as Red Rod encapsulation of reference elements means no silver ions and therefore less risk of clogging.

    Fast and accurate response thanks to the symmetrical electrode chain formed by the internal and external Red Rod reference elements.

    Stable signal as the Red Rod Technology protects the reference elements from light interference. Saturated KCI salt-bridge aids stable liquid junction potential.

    The symmetry of Red Rod electrodes means that the iso pH is the same as the zero pH which provides highly reproducible results even when temperature fluctuations occur. The figure compares the measurements performed with a general-purpose Red Rod electrode and a traditional combined electrode. A MeterLab setup was used to measure certified standard pH solutions, pH 7.000 thermostated at 50C and pH 4.005 thermostated at 25C. The figure shows the fast response of the Red Rod electrode to changes in pH and temperature (curves offset to increase readability).

    ELECTRODES

    Your guarantee of reproducible results

    Red Rod combined pH electrode compared to traditional combined pH electrode

    6,8

    6,3

    5,8

    5,3

    4,8

    4,3

    3,8

    0 10 20 30 40 50 60 70

    pH

    Time (minutes)

    Traditionaltechnology

    Red Rod technology

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se8

    The Right Electrode for your Application

    Combined pH electrodes

    ELECTRODES

    There is a Radiometer Analytical electrode for every application. The above table gives examples of the many applications for which Radiometer Analytical electrodes can be used. Where possible, choose an electrode which is Recommended but where one electrode is required for several applications, it may be

    necessary to select one which is Acceptable.Full specifications of the electrodes featuredin the table are given on the following pages.In addition to your application, there are other considerations when choosing an electrode. The length and diameter obviously depend on the sample size and

    Applications PHC

    2001

    pHC

    2002

    pHC

    2003

    pHC

    2005

    pHC

    2011

    pHC

    2015

    pHC

    2051

    pHC

    2085

    pHC

    2401

    pHC

    2441

    pHC

    2501

    pHC

    2601

    pHC

    2701

    pHC

    3001

    pHC

    3005

    pHC

    3006

    pHC

    3006

    L

    pHC

    3011

    Alkaline solutions

    Aqueous solutions

    Blood

    Education purposes

    Emulsions

    Fat/cream/cosmetics

    Field use

    Gel electrode

    Hops/beer

    Hydrofluoric acid

    Lacquer

    Liqueur etc.

    Long length >150 mm

    Low ionic strength

    Microsamples

    Milk

    Non-aqueous media

    Oil

    Paint

    Paper

    Penetration (cheese)

    Photo baths

    Sea water, swimming pools

    Soil

    Solids, high content of

    Suspensions

    Temperature, high or varying

    Temperature sensor, built-in

    TRIS buffer

    Viscosity, high

    Voltammetry

    Yogurt, curdled milk

    sample vessel. Radiometer Analytical offers electrodes with various lengths for specialist applications and small diameters for microsamples.

    Risk of damageAcceptableRecommended Not Recommended

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    9

    Combined pH electrodes Reference electrodesGlass electrodes

    When measuring at high temperatures, theelectrochemical system within the electrode needs to be considered. Radiometer Analytical offers Ag/AgCl electrodes specially designed for high temperaturemeasurements.To avoid chloride interference, a reference

    ELECTRODES

    electrode with a chloride-free reference system must be used (e.g. Hg/Hg2SO4 with K2SO4 salt-bridge) or a reference electrode with a double salt-bridge construction.

    Applications pHC

    3031

    pHC

    3081

    pHC

    3105

    pHC

    3131

    pHC

    3359

    XC16

    1

    PHG

    200

    pHG

    201

    pHG

    211

    pHG

    301

    pHG

    311

    XG25

    0

    REF

    200

    REF

    201

    REF

    251

    REF

    321

    REF

    361

    XR82

    0

    Alkaline solutions

    Aqueous solutions

    Blood

    Education purposes

    Emulsions

    Fat/cream/cosmetics

    Field use

    Gel electrode

    Hops/beer

    Hydrofluoric acid

    Lacquer

    Liqueur etc.

    Long length >150 mm

    Low ionic strength

    Microsamples

    Milk

    Non-aqueous media

    Oil

    Paint

    Paper

    Penetration (cheese)

    Photo baths

    Sea water, swimming pools

    Soil

    Solids, high content of

    Suspensions

    Temperature, high or varying

    Temperature sensor, built-in

    TRIS buffer

    Viscosity, high

    Voltammetry

    Yogurt, curdled milk

    Risk of damageAcceptableRecommended Not Recommended

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se10

    To meet your analysis needs, combined pH electrodes are available with a variety of lengths, diameters and reference systems.All our electrodes are delivered with a Certificate of Conformity signed by the Total Quality Manager. This specifies the sensitivity,zero pH, response time and batch number of the electrode.You may need a cable or plug adapter to connect your chosen electrode to your meter.

    Combined pH ElectrodesRadiometer Analytical - Hach Lange

    ELECTRODES

    Temperature Sensors

    Type T101 T201 T202 T203

    Part no. E51M003 E51M001 E51M002 E51M008 Temperature range -10 105C -10 105C -10 105C -10 -105C Diameter (mm) 7.5 7.5 7.5 7.5 mm Material Glass Glass Glass Glass Connection PYE Cinch Cinch RJ9

    InstrumentPHM83/85ION83/85CDM83

    PHM2XXCDM2XXPHM9X

    PHM2XXCDM2XXPHM9X

    SensION+

    For pH measurements and measurements with ion-selective electrodes and conductivity cells, use of a temperature sensor is recommended because temperature affects the results.

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    11

    Radiometer pH Electrodes

    Applications General purpose Alkaline samples

    Model pHC2001 pHC2002 pHC2003 pHC2401 pHC2005 pHC2085 pHC2011 pHC2015 Probe part no. BNC E16M313 E16M315 E16M334 E16M400 E16M500 E16M345 E16M317 E16M318 Probe part no. Type 7 E16M336 E16M337Combination probe YES YES YES YES YES YES YES YES Reference system Red Rod Red Rod Red Rod Red Rod Red Rod Red Rod Red Rod Red Rod Liquid junction Porous pin Porous pin Porous pin Annular ring Porous pin Porous pin Porous pin Porous pin pH range 0 12 0 -12 0 -12 0 -12 0 -12 0 -12 0 -14 0 -14 Temperature included NO NO NO NO NO YES NO NO Temperature range -10 -100C -10 -100C -10 -100C -10 -100C -10 -100C -10 -100C 0 -100C 0 -100C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Minimum sample depth 18 mm 18 mm 18 mm 14 mm 14 mm 14 mm 18 mm 14 mm Special features Long Long Robust Temp. sensor Robust Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl

    *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibility

    Applications Surface measurement Soils Cl-sensitive

    samples Viscous samples High KCl flow General purpose

    Model pHC2441 pHC2051 pHC2501 pHC2601 pHC2701 pHC3001 pHC3081

    Probe part no. BNC E16M320 E16M319 E16M321 E16M322 E16M323 E16M300 E16M301* E16M344

    Probe part no. Type 7 E16M339Combination probe YES YES YES YES YES YES YES Reference system Red Rod Red Rod Red Rod Red Rod Red Rod Ag/AgCl Ag/AgCl Liquid junction Annular ring Porous pin Double/Porous Sleeve Annular ring Porous pin Porous pin pH range 0 -12 0 12 0 -12 0 -12 0 -12 0 -12 0 -12 Temperature included NO NO NO NO NO NO YES Temperature range -10 -100C -10 -100C -10 -100C -10 -100C -10 -100C 0 -80C 0 -80C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Minimum sample depth flat 18 mm 18 mm 18 mm 14 mm 18 mm 18 mm Special features Temp. sensor Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl 3 M KCl + sat. AgCl

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se12

    Radiometer pH Electrodes

    Applications General purposeGeneral purpose

    General purpose

    Alkaline samples

    Alkaline samples

    General purpose

    Model pHC3006 pHC3006L pHC3005 pHC3011 GK2401B GK2401C

    Probe part no. BNC E16M306* E16M307* E16M302BNC E16M303* E16M324*

    Probe part no. Type 7 945-261 945-252Combination probe YES YES YES YES YES YESReference system Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Red Rod Red RodLiquid junction Porous pin Porous pin Porous pin Porous pin Porous pin Porous pinpH range 0 -12 0 - 12 0 - 12 0 - 14 0 - 14 0 - 14Temperature range 0 - 80C 0 - 80C 0 - 80C 0 - 80C 0 - 100C -10 - 100CLower diameter 6.5 mm 6.5 mm 12 mm 12 mm 9,5 mm 9,5 mmMinimum sample depth 14 mm 14 mm 12 mm 18 mm 16 mm 16 mmSpecial features Small Long, small Robust

    Salt-bridge solution 3 M KCl + sat. AgCl 3 M KCl + sat.

    AgCl 3 M KCl + sat.

    AgCl 3 M KCl + sat.

    AgCl Sat. KCl Sat. KCl

    Applications Microsamples Microsamples General-purpose Gel-filledPenetration

    Gelfilled Penetration

    Model XC161 pHC3359 pHC3105 pHC3131 pHC3031

    Probe part no. B10C161* E16M343BNC E16M308* E16M328* E16M325*

    Combination probe YES YES YES YES YES Reference system Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Liquid junction Porous pin Fibre Opening Opening Porous pin pH range 0 - 12 0 - 12 2 - 12 2 - 12 0 - 12 Temperature included NO NO NO NO NO Temperature range 0 - 80C 0 - 80C 0 - 80C 0 - 80C 0 - 80CLower diameter 5 mm 3 mm 12 mm 8 mm 8 mm Minimum sample depth 8 mm 2 mm 18 mm 14 mm 14 mm Special features Robust Salt-bridge solution 3 M KCl + sat. AgCl 3 M KCl + sat. AgCl Solid gel (3 M KCl) Solid gel (3 M KCl) 3 M KCl + sat. AgCl

    ELECTRODES

    *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibility

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    13

    Single and combined metal electrodes can be used for redox measurements, redox titrations or potentiometric techniques hereas double metal electrodes are ideal for imposed current potentiometric titration. Radiometer Analyticals electrode range features single, double and combined metal electrodes with latinum, silver, gold, antimony and glassy carbon sensing elements.

    Metal and Combined Metal ElectrodesRadiometer Analytical - Hach Lange

    ELECTRODES

    Metal Electrodes and Combined Metal Electrodes

    Applications General- purpose Karl

    Fischer titrations

    Redox meas.

    Silver halides Titra-tion

    pH meas. titration

    Redox meas.

    Type M241Pt M231Pt M231Pt2 MC3051Pt M295Ag M291Ag MC2095Sb MC201Au-8Part no. E31M001 E31M002* E32M001 E31M003* E34M003 E34M002* E36M001 E36M005

    Sensing element Platinum plate 5 x 5 mmPlatinum wire

    1 mm2 platinum

    wires 1 mm Platinum ring Silver rod Silver rodAntimony

    rodGold wire

    1 mm

    Temperature range -10 100C -10 100C -10 100C 0 80C -10 100C 0 80C 0 60C -10 100C

    Lower diameter 7.5 mm 8 mm 12 mm 12 mm 7.5 mm 8 mm 12 mm 12 mmReference system Ag/AgCl Hg/Hg2SO4 Red RodLiquid junction Porous pin Porous pin Porous pin

    Connection Banana plug Screw cap 2 x banana Screw cap Banana plug Screw cap BNC plug BNC plug

    Salt-bridge solution 3 M KCl with sat. AgCl Sat. K2SO4 Sat. KCl

    Minimum sample depth 18 mm 18 mm 18 mm 14 mm 18 mm 14 mm Special features Long Long Robust Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Recommended Reference Electrode

    *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibility

    Applications Voltammetry Voltammetry RedoxType XM110 XM120 XM140 XM150 M291C

    Part no. B35M110* B35M120* B35M140* B35M150* E36M003*

    Sensing element Platinum wire 1 mmPlatinum plate 5 x

    5 mmPlatinum plate 8 x

    8 mmPlatinum disc

    10 mmGlassy carbon rod

    3 mmTemperature range -10 100C -10 100C -10 100C -10 100C 0 60CDiameter 8 mm 8 mm 8 mm 12 mm 8 mmConnection Screw cap Screw cap Screw cap Screw cap Screw cap

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se14

    pH glass electrodes from Radiometer Analytical are made with highly shock-resistant glass, making them extremely tough. The average lifetime of a correctly maintained glass pH electrode is approximately 2 years.Certain electrodes are made with special glass for pH measurements in strongly alkaline solutions. These electrodes allow measurements within the 0 - 14 pH range without significant deviation from the theoretical response.Glass pH electrodes are always used in combination with reference electrodes. The zero pH of Red Rod glass pH electrodes when used with their recommended reference electrode is approximately pH 6.65. The zero pH of glass pH electrodes is approximately pH 6.65 when measured against a calomel reference electrode (e.g. REF421, XR110) and approximately pH 7.25 when measured against an Ag/AgCl reference electrode (e.g. REF321).

    Glass pH ElectrodesRadiometer Analytical

    Glass pH electrodes

    ELECTRODES

    Applications Microsamples General-purpose Alkaline samples

    General purpose

    Alkaline samples

    Alkaline samples

    Model pHG200 pHG201 pHG211 pHG301 pHG311 XG250

    Probe part no. E11M002BNC E11M006BNC E11M003BNC E11M001* E11M004* B10B250*

    Combination probe NO NO NO NO NO NOReference system Red Rod Red Rod Red Rod Ag/AgCl Ag/AgCl Ag/AgClLiquid junction pH range 0 - 12 0 - 12 0 - 14 0 - 12 0 - 14 0 - 14Temperature included NO NO NO NO NO NOTemperature range 10 - 100C -10 - 100C 10 - 100C 0 - 80C 0 - 80C 0 - 80CLower diameter 4 mm 7.5 mm 7.5 mm 12 mm 12 mm 10 mm**Minimum sample depth 4 mm 7 mm 7 mm 12 mm 12 mm 12 mmSpecial features Salt-bridge solution

    Recommended Reference Electrode

    REF200 REF201/251 REF201 for general use

    REF201/251 REF201 forgeneral use REF321 REF321

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    15

    During measurement, the salt-bridge junction (also called liquid junction protection tube) prevents the reference electrode from being contaminated by the media and vice-versa. It consists of a glass tube terminated by a liquid junction. Always ensure the filling solution used corresponds to the application.

    A reference electrode provides a stable potential whatever the measurement conditions. The main differences between reference electrodes are the type of reference system and the liquid junction. Radiometer Analytical offers electrodes using both Red Rod and traditional technology.Electrodes with a double junction are mostly designed for measurements using ion-selective electrodes or samples sensitive to Cl- or K+. Sleeve junctions have a high flow to prevent the risk of clogging. Porous pins are used for general applications. Fibre reference electrodes have a slow flow to avoid contamination of the media.

    Reference ElectrodesRadiometer Analytical

    Salt-bridge junctions

    Reference Electrodes

    *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibility

    Applications Micro-samples General purpose

    General purpose

    General purpose

    Non-aqueous media Voltammetry Impedance

    Model REF200 REF201 REF251 REF321 REF361 XR300 XR820

    Probe part no. E21M008 E21M009 E21M001 E21M002* E21M003 B20B300* B20C820*

    Reference system Red Rod Red Rod Red Rod Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl

    Liquid junction Porous pin Porous pin Porous pin / porous pin Porous pin Glass sleeve Porous pin Porous pin /

    fibre Temperature range -10 -100C -10 -100C -10 -100C -5 -80C -5 -80C -5 -80C -5 -80C Lower diameter 4 mm 7.5 mm 12 mm 8 mm 12 mm 8 mm 8 mm

    Special features For use with pHG200 Double junction

    Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl 3 M KCl with sat. AgCl 3 M KCl with

    sat. AgCl Sat. KCl + sat.

    AgCl Sat. KCl + sat. AgCl upper res.

    ELECTRODES

    Type AL100 AL110 AL120

    Part no. B40A520 B40A550 B40A610

    Lower diameter 12 mm 8 mm 8 mm

    Junction Ceramic Ceramic Ceramic

    Special features for 7.5 or 8 mm ref. electrodes

    for ref. electrodes with ground joint

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se16

    The use of ion-selective electrodes constitutes a quick and cost-effective method of determining ionic activity.Due to their quality and diversity, Radiometer Analytical ion-selective electrodes efficiently solve various analytical problems of species in solution.Each electrode is carefully checked before packing and is delivered with an individual control report including information such as the response curve, checkpoint value and slope.

    Ion-selective ElectrodesRadiometer Analytical - Hach Lange

    ELECTRODES

    Ion-selective Electrodes

    Ion Species Br - Ca ++ Cl - Cl - CN - Cu ++ F -

    Model ISE25Br ISE25Ca ISE25Cl ISE/HS25Cl ISE25CN ISE25Cu ISE25F

    Probe part no. E41M001* E41M002* E41M003* E41M004* E41M005* E41M006* E41M007*

    Combination probe Concentration range (M) 10 -6 -100 2 x 10 -6 -100 5 x 10 -5 -100 10 -6 -100 5 x 10 -7 -10 -3 10 -6 -100 5 x 10 -7 -100 Concentration range (ppm) 0.08 -80000 0.1 -40000 1.8 -35000 0.04 -35000 0.013 -25 0.06 -60000 0.01 -20000 Temperature range 0 -60C 0 -50C 0 -60C 0 -60C 0 -60C 0 -60C 0 -60C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 7 mm pH range 2 -14 4 -12 2 -14 2 -4 9 -14 0 -14 5 -11

    Sensor type Solid-state PVC membrane Solid-state Solid-state Solid-state Solid-state Solid-state

    Interfering ions I -, S2-, CN -, SCN Zn2+, Pb2+ I -, CN -, Br -,

    SCN I -, CN -, Br -,

    SCN I -, Br -, S2 HgS, Ag+, Cl OH

    Recommended reference electrodes REF251

    REF201 REF251 REF251 REF251

    REF201 REF251

    REF201 REF251

    REF201 REF251

    *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibility

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    17

    Ion-selective Electrodes

    Ion Species F - I - K+ Na+ NH4 + NO3 - Pb++

    Model ISEC301F ISE25I ISE25K ISE21Na ISE25NH4 ISE25NO3 ISE25Pb

    Probe part no. E41M017* E41M008* E41M009* E41M010* E41M013* E41M014* E41M015*

    Combination probe Concentration range (M) 5 x 10 -7 -100 10 -6 -10 -1 2 x 10 -6 -100 2 x 10 -6 -100 3 x 10 -6 -100 3 x 10 -6 -100 10 -6 -100 Concentration range (ppm) 0.01 -20000 0.13 -13000 0.08 -40000 0.04 -20000 0.06 -20000 0.2 -60000 0.2 -200000 Temperature range 0 -50C 0 -60C 0 -50C 0 -70C 0 -50C 0 -50C 0 -60C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm pH range 5 -7 2 -12 2 -12 5 -12 3 -8 3 -10 3 -7

    Sensor type Solid-state Solid-state PVC membrane Glass PVC

    membrane PVC

    membrane Solid-state

    Interfering ions OH CN -, Hg2+, Br -, SCN NH4 +, Rb+ Li+, NH4 +, Rb+, Ag+ K+

    Cl -, Br -, NO2 -

    Hg2+, Cu2+, Ag+

    Recommended reference electrodes

    REF201 REF251

    REF201 REF251 REF251 REF251

    REF201 REF251 REF251

    *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibility

    ELECTRODES

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se18

    It is important to choose a cell with the right construction and geometry for your particular application and working conditions.Radiometer Analytical offers conductivity cells for a wide variety of applications.2-pole cells have a traditional design based on two plates of platinum. They are ideal for routine measurement of conductivity and for use with a sample changer due to the easy rinsing. 3-pole cells consist of 3 platinum rings which facilitate optimal shielding during measurement.

    Conductivity CellsRadiometer Analytical

    ELECTRODES

    Conductivity Cells

    Applications General purpose General purpose

    General purpose

    General purpose

    General purpose

    Sample changer

    Resistant media

    Viscous Titration

    Model CDC536T CDC836T CDC641T CDC745-9 XE100 CDC741T CDC267-9 CDC241-9

    Probe part no. RJ45 E61M021 E61M020 E61M022 E61M013* B60E100* E61M023 E61M011* E61M008*

    Probe part no. MAB6 B15B001 E61M012Body material Epoxy1 Epoxy1 Glass Epoxy Glass Glass Glass Glass

    Cell constant (cm-1) 1.0 1.0 0.85 1.0 1.0 1.0 0.1 1.0

    Number of poles 3 3 2 2 2 2 2 2Platinised NO YES YES YES YES YES NO NO

    Temperature included YES YES YES NO NO YES NO NO

    Max. temperature 80C 80C 100C 100C 100C 100C 100C 100C

    Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm

    Minimum sample depth 35 mm 35 mm 14 mm 14 mm 10 mm 10 mm 26 mm 10 mm

    *Screw cap electrode. Requires CL143connection cable (part no. A94L143) for sensION+ meter compatibility1) removable epoxy tube for easy rinsing (can be replaced by glass tube)

    Conductivity measurement is temperature dependent (if the temperature increases so does the conductivity value). When performing conductivity measurements, it is advisable to choose a cell with a built-in temperature sensor or use a separate sensor.

    Remember to calibrate your conductivity cell regularly as the cell constant may vary due to changes in electrode surface due to contamination, for example.

    Some tips

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    19

    Recommended conductivity cells by application

    Applications/Characteristics

    CD

    C56

    6T

    CD

    C86

    6T

    CD

    C56

    5

    CD

    C64

    1T

    CD

    C74

    5-9

    XE10

    0

    CD

    C51

    1T

    CD

    C74

    1T

    CD

    C86

    1T

    CD

    C26

    7-9

    CD

    C24

    1-9

    CD

    C74

    9

    Wide conductivity range (general purpose) x x x xVarious aqueous and non-aqueous media x x xVery strong acids and bases xUse with sample changer xBuilt-in temperature sensor x x x x x xContinuous measurements x x xMicrosamples xFlow measurements xTitration xSalinity (high conductivity) x xPure water xMeets requirements of USP 24-NF19 x xMeets requirements of EP 2.2.38 xUse in glass tubes xPlastic body x x x x xViscous media xHighly resistant media xField use x x x x

    Conductivity Cells

    Applications GeneralpurposeGeneralpurpose

    Generalpurpose

    Generalpurpose Pure Water

    Strong acid basis

    Microsamples

    Type CDC566T CDC866T CDC565 CDC745-9 CDC511T CDC861T CDC749Part no. MAB6 E61M010 E61M015 E61M003 E61M009 E61M016 E61M014Part no. screw cap E61M013Body Epoxy1) Epoxy1) Epoxy Epoxy TPX2) Glass GlassCell. Constant (cm-1) 3) 1.0 1.0 1.0 1.0 1.0 1.0 1.7Number of poles 4 4 4 2 4 4 2Platinised NO YES NO YES NO YES YESTemperature sensor YES YES NO NO YES YES NODiameter (mm) 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 4 mmMax. temperature 80C 80C 80C 100C 80C 100C 100CMin. immersion depth 35 mm 35 mm 30 mm 14 mm 3 ml4) 35 mm 4 mmCDM210/CDM230 YES YES YES YES3) YES YES YES

    1) Removable epoxy tube for easy rinsing(can be replaced by glass tube - see accessories)2) Polymethylpentene. Removable part for easy rinsing

    ELECTRODES

    3) The cell constant is determined experimentally for each cell and the value is given as a guideline only4) Minimum sample volume

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se20

    The use of standards manufactured by an accredited laboratory gives you complete confidence in the traceability chain and calculated uncertainties. Radiometer Analytical is part of the Hach Lange group whose Calibration Laboratory, located in Berlin, is accredited for the calibration of certified pH and conductivitystandards by DKD, the German national accreditation authority. This accreditation (No. DKD-K-47901) is recognised in more than 35 countries. All standards are formulated in compliance with NIST,IUPAC and DIN19266 specifications (1 p. 21).IUPAC Series certified pH standards are fully traceable to the Standard Hydrogen Electrode through Certified Reference Material produced by the Primary Laboratory of either NIST or DFM (2 p. 21). Radiometer Analytical certified conductivity standards are fully traceable to SI units via Certified Reference Materials manufactured by NIST. They are prepared and calibrated according to the internationally recognised demal scale laid down by the International Organisation of Legal Metrology (OIML Recommendation No. 56).

    Accredited Calibration Laboratory

    CERTIFIED STANDARDS

    ** The NaCl 25 certified conductivity standard comes in a 250 ml glass bottle.

    Radiometer Analytical certified standards are fully traceable. Certificates are always included with the buffer solutions.

    Type Value Qty Part No.

    KCl 1D 111.3 mS/cm 0.5% at 25C 500 ml S51M001KCl 0.1D 12.85 mS/cm 0.35% at 25C 500 ml S51M002KCl 0.01D 1408 S/cm 0.5% at 25C 500 ml S51M003NaCl 0.05% 1015 S/cm 0.5% at 25C 500 ml S51M004NaCl 25 25.0 S/cm 5% at 25C 250 ml S51M013**

    Certified conductivity standards

    Type Qty Part No.

    pH4.01 250 ml LZW9463.99pH7.00 250 ml LZW9464.98pH10.00 250 ml LZW9471.99

    Buffers for certified sensION+

    * Radiometer Analytical formulation.

    Type Value Qty Part No.

    pH1.679 pH 1.679 0.010 at 25C 500 ml S11M001pH4.005 pH 4.005 0.010 at 25C 500 ml S11M002pH6.865 pH 6.865 0.010 at 25C 500 ml S11M003pH7.000* pH 7.000 0.010 at 25C 500 ml S11M004pH7.413 pH 7.413 0.010 at 25C 500 ml S11M005pH9.180 pH 9.180 0.010 at 25C 500 ml S11M006pH10.012 pH 10.012 0.010 at 25C 500 ml S11M007pH12.45 pH 12.45 0.05 at 25C 500 ml S11M008

    IUPAC Series certified pH standards

    Type Value Qty Part No.

    pH4.00 pH 4.00 at 25C 500 ml S11M012pH7.00 pH 7.00 at 25C 500 ml S11M013pH10.00 pH 10.00 at 25C 500 ml S11M014

    4-7-10 Series

    A

    B

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    21

    Totally reliable packaging

    Each standard is delivered in an airtight can and is supplied with a film-wrapped Certificate of Conformityand Traceability as well as a DKD Calibration Certificate specifying the exact measured value and calculated expanded uncertainty (k=2) for each batch of pH and conductivity solution.

    (1) Except pH7.000 formulated by us according to NIST, IUPAC and DIN19266 specifications of pH6.865 and pH7.413.(2) Dansk Fundamental Metrologi A/S is accredited for pH measurements by the Danish Accreditation and Metrology Fund (DANAK) (no. 255).(3) 4-year guarantee for pH standards (2 years for pH 12.45). 2-year guarantee for conductivity standards (1 year for the 25 S/cm). The guarantee is valid from the date of the Certificate of Conformity and Traceability and only applies to standards kept unopened in the sealed can in compliance with the storage recommendations specified in the certificate.

    Safe storagethanks to the airtight can.

    BInternational accreditationa DKD Calibration Certificate proves the traceability to national standards.

    GLP - right from the startthe date of opening can be marked directly on the bottle.

    Recommended shelf lifethe observed typical shelf life after opening is printed on the bottle, ensuring timely use(2-3 months depending on the standards).

    A guaranteed valuethe nominal value of the standard is guaranteed until first opening, even after several years storage(3).

    GLP - every daythe number of uses can be marked directly on the bottle in line with Good Laboratory Practice.

    A useful referencea pH or conductivity temperature dependence table is printed on the bottle.

    AProven traceabilityeach standard comes with its own Certificate of Conformity and Traceability.

    Accurate valuesthe nominal value and the tolerance of pH standards are given with a resolution of 3 significant decimals.

    Glossary & useful links

    NIST National Institute of Standards and Technology www.nist.govIUPAC International Union of Pure and Applied Chemistry www.iupac.orgDFM Danish National Metrology Institute www.dfm.dtu.dkDKD Deutscher Kalibrierdienst www.dkd.euDANAK Danish Accreditation and Metrology Fund www.danak.orgOIML International Organisation of Legal Metrology www.oiml.org

    PACKAGING

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se22

    Electrode Maintenance

    MAINTENANCE

    Reference element Solutions

    Red Rod KClL and KClC KS100 and KClCAg/AgCl (pHC3xxx /REF3xx) KClAgAg/AgCl (XCxxx/ XRxxx) KS120

    Calomel KClL and KClC KS100 and KClCHg/Hg2SO4 KS160

    Type Description Qty Part No.

    RENOVON Normal Cleaning Solution 250 ml S16M001RENOVOX Xtra Strong Cleaning Solution 250 ml S16M002KS400 Pepsin in HCl Solution 250 ml C20C370KS410 Thiourea Solution 250 ml C20C380

    Type Description Qty Part No.

    KS100 Saturated KCl Solution 500 ml C20C300KClL Saturated Solution of KCl 100 ml S21M002KClL-30 Saturated Solution of KCl, 30 ml S21M010KClC KCl Crystals 15 g S21M001KClAg 3 M KCl Solution Saturated with AgCl 100 ml S21M004KClAg-30 3 M KCl Solution Saturated with AgCl 30 ml S21M011KS110 KCl Solution 3 M 500 ml C20C320KS120 Saturated KCl + AgCl Solution 500 ml C20C310KS120-30 Saturated KCl + AgCl Solution 30 ml S21M009KS160 Saturated K2SO4 Solution 500 ml C20C500KS160-30 Saturated K2SO4 Solution 30 ml S21M007LiCl-30 1 M LiCl Solution 30 ml S21M008

    Selecting the right filling solution

    Maintenance solutions

    Filling and storage solutions forcombined and reference electrodes

    The maintenance requirements of electrodes vary according to the application. After measurements in aqueous solutions, cleaning with a mild solution such as RENOVON is sufficient. However, when the solutions contain protein, for example, stronger cleaning agents such as RENOVOX or Pepsin in HCl are required. For junctions contaminated with sulphides or AgCl precipitate, Radiometer Analyticals Thiourea Solution is ideal. The operating instructions provide cleaning instructions for each type of electrode.

    Maintenance solutions

  • BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se

    23

    Electrode plug Instrument socket Part no.

    BNC Type 7 A94P800

    Type 7 BNC A94P802

    2 x banana BNC A94P801

    BNC DIN A94P806

    BNC Banana A94P807

    Banana 4 mm

    Banana US 2 mm X41V001

    Banana 4 mm Type 7 809-147

    UHF MAB6 A94P001

    MAB6 UHF+PYE A94P002

    Plug adaptersfor screw cap electrodes

    Instrument socket Type Part no.

    Banana CL111 A94L111

    P2 CL112 A94L112

    DIN CL113 A94L113

    BNC CL114 A94L114

    Type 7 CL116 A94L116

    UHF (PL259) CL119 A94L119

    2 x banana CL120 A94L120

    LEMO 5 mm CL129 A94L129

    MAB6 CL136 A94L136