pH, Conductivity and Ionselectiv Measurements sensION+ portable meters are compact, ... pH 2,00/4,01 /7,00 and 10,00 at 25C Manual calibration using the buffer solution of ... pH-meter EC7 Benchtop ...

  • Published on
    17-May-2018

  • View
    225

  • Download
    8

Transcript

www.bergmanlabora.seDITT LAB - VRT JOBBpH, Conductivity and Ionselectiv MeasurementsBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se2Hach sensION+ portable meters are compact, rugged lightweight, and ideally suited for field measurements.Portable Meters Hach sensION+ SensION+ Portable MetersWaterproof IP67, shock resistant housing Large backlit graphic screen with icon navigation Simultaneous display of various parameters Combined electrodes with built-in temperature probe and watertight connector Carrying case designed to be a portable laboratory! SensION+ portable meters, technical specificationsPORTABLE METERS Measuring rangespH: -2.00 to 19.99mV: +/- 1400Conductivity: 0.01S/cm to 500 ms/cmTDS: 0 mg/l to 500 g/lSalinity: 0 to 50 g/l NaClDissolved OxygenSaturation: 0 to 250 % (25C)Concentration 0 to 22 mg/l (25C)Temperature: -20 to 150C (0 to 50C for DO)Temperature compensationAutomatic thanks to the Pt 1000 built-in in theprobes.Temperature correction for conductivityLinear correction factor from 0 to 9,99 %/C(default value 2 %)Reference temperature 20 or 25CTDS conversion factor0 to 4,44 (default value 0,64)Measuring modeUpon stabilisation or continuousCalibrationpH1,2 or 3 calibration pointsAutomatic recognition of buffer solutionspH 2,00/4,01 /7,00 and 10,00 at 25CManual calibration using the buffer solution of your choiceRestore factory calibration optionmVAutomatic recognition of a standard solution 220 mV at 25CManual calibration using the standard solution ofyour choiceRestore factory calibration optionConductivity1,2 or 3 calibration pointsStored calibration solutions 147 S/cm, 1413S/cm, 12,88 mS/cm and 111,8 mS/cm at 25CManual calibration using the standard solution ofyour choiceRestore factory calibration optionDissolved Oxygen1 or 2 calibration pointsManual calibration at 0 and 100 % saturationTemperature adjustmentDrift correction of the temperature probe at 25 and 85CDisplayLCD with backlightSimultaneous display of several parametersIcon navigationPower supply3 x AA batteries, battery life depends on model,above 500 hours for pH-meterAutomatic switch off after 5 min. (this function can be disabled)ConnectionWatertight electrode connector MP-5 (5 contacts) for PH1 / EC5MP-8 (8 contacts) for MM150Meter housing featuresABS, waterproof IP67Dimensions 186 x 73 x38mmWeight 300 gWorking environmentWorking T: 0 to 50CStorage T: -15 to 65CRelative humidity rate BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se3Electrodes for SensION+ Portable MetersSpecifications Combined pH General use Combined pH waste water Combined pH Low conductivity high temperature Combined pH puncture type Combined pH puncture typeModel 5050T 5051T 5052T 5053T 5054TSpecial feature Gel With working protector open junctionWith working protector PTFE junctionBuilt-in T probe 2 junctionsRemovable steel knife,Built-in TMeasuring range 0 to 14 pH 2 to 14 pH 0 to 14 pH 2 to 14 pH 2 to 14 pHTemperature range 0 to 80 C 0 to 80 C 0 to 100 C 0 to 60 C 0 to 60 CTemperature probe Pt1000 Pt1000 Pt1000 Pt1000 Pt1000Dimensions (under head) 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mmSensitive component Glass Glass Glass Glass GlassBody material Polycarbonate Glass Glass Stainless steel Stainless steelFilling Gel Solid Gel Solid SolidConnector MP-5 MP-5 MP-5 MP-5 MP-5Cable length 1 m 1 m 1 m 1 m 1 mProduct number LZW5050T.97.002 LZW5051T.97.002 LZW5052T.97.002 CRI5053T.99 CRI5054TC.99PORTABLE METERSSpecifications Conductivity General useConductivity Difficult samples Multi* Multi*Model 5060 5062 5048 5059 Special feature - Rugged titanium body pH/Conductivity/ORP pH/Conductivity Measuring range 0,2 S/cm up to 200 mS/cm 5 S/cm up to 50 mS/cm0 to 14 pH 25-200 mS/cm +/- 2000 mV0 to 14 pH 5 S/cm to 30 mS/cm +/- 2000 mVTemperature range 0 to 80 C 0 to 80 C 0 to 80 C 0 to 80 C Temperature probe Pt1000 Pt1000 Pt1000 Pt1000 Dimensions (under head) 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm 12 mm x 85 mm Sensitive component Platinum Platinum pH: Glass Cond & Redox: PlatinumpH: Glass Cond: TitaniumBody material Polycarbonate Titanium Polycarbonate Polycarbonate Filling - - Gel Gel Connector MP-5 MP-5 MP-8 MP-8 Cable length 1 m 1 m 1 m 1 m Product number LZW5060.97.0002 LZW5062.97.0002 LZW5048.97.0002 LZW5059.97.0002 *Only compatible with sensION+ multimeter MM150BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se4Hach sensION+ Benchtop Meters are designed to be all-in-one working stations, ready for a widevariety of applications, and come complete withintegrated electrode holder and magnetic stirrer.Benchtop Meters Hach sensION+SensION+ Benchtop MetersHousing and keyboard splashproof IP42 Large graphic display with backlight Electrode parking positions Colour coded calibration flasks with magnetic rod Electrode holder fitted with a safe cable fastener Built-in magnetic stirrer controlled from the instrument BENCHTOP METERS Parameters PH3 Benchtop pH-meterPH31 GLP Benchtop pH-meterEC7 Benchtop conductivity meterEC71 GPL Benchtop conductivity meterMM374 GLP Benchtop multimeterTemperature x x x x xpH x x xConductivity x x xResistivity x xSalinity x x xTDS x xORP/Redox x x xNitrates xFluoride xSodium xChloride xAmmonium xAmmonia xSpecificationsNo of measuring channels 1 1 1 1 2GLP functions x x xPC or printer output x x xProduct number LPV2000.98.0002 LPV2100.98.0002 LPV3010.98.0002 LPV3110.98.000 LPV4110.98.0002BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se5SensION+ benchtop meters, technical specificationsMeasuring rangespH: -2.00 to 19.99mV: +/- 2000Conductivity: 0,01/0.001*S/cm up to 500/1000** ms/cm(*with Constant=0,1 cm-1, **with Constant=10 cm-1)Resistivity: 0 to 100 MOhmsTDS: 0 mg/l to 500 g/lSalinity: 5,85 mg/l to 311,1g/l NaClISE: 10-5 M to 10-1 MTemperature: -20 to 150CTemperature compensationAutomatic with Pt 1000 or 10 kOhms temperatureprobeManual if no T sensor connected.Temperature correction for conductivityLinear correction factor from 0 to 9,99%/C (default value 2%)Correction factor for natural waters following UNEEN 27888 Except EC7Reference temperature 20 or 25CTDS conversion factor0 to 4,44 (default value 0,64)CalibrationAdjustable calibration alarmAutomatic rejection of electrodes in poor conditionpH1,2 or 3 calibration pointsAutomatic recognition of buffers among following series: pH 2,00/4,01/7,00 and 10,00 at 25C) pH 1,679/4,006/6,865/7,00/9,18/10,012/12,454 at 25C - Except PH3Series of 3 free selectable buffer values - Except PH3Manual calibration using any value -Except PH3Manual entry of calibration results - Except PH3Restore factory calibration option mVAutomatic recognition of a standard 220 mV at 25CManual calibration using any value - Except PH3Manual entry of calibration values - Except PH3Restore factory calibration option - Except PH3Conductivity1, 2 or 3 calibration pointsSelection of standards in the following series Molar 147 S/cm, 1413 S/cm, 12,88 mS/cm,111,8 mS/cm at 25C Demal 1049 S/cm, 12,85 mS/cm, 111,31 mS/cm at 25C Except EC7 NaCl 1014,9 S/cm for salinityManual calibration using any value Except EC7Manual entry of the cell constantRestore factory calibration optionIonmetry (ISE)2 to 5 calibration pointsSeries of 5 users selectable calibration solutionsStorage of 4 calibration curvesTemperature adjustmentDrift correction of the temperature probe at 25 and 85C - Except PH3 and EC7Measuring modeUpon stabilisation, continuous or by time - ExceptPH3 and EC72 independant measuring channels for MM340 and MM374GLP functions Except PH3 and EC7340 results stored for each channel and 9 calibrationresultsDate/Time, sample ID, user IDConnectionsCombined/indicator electrode: BNCReference electrode: banana 5 mmConductivity cell: 8 contact telephone plugT: 5 mm banana or 4 contact telephone plugData transfer Except PH3 and EC7RS232 output for PC or printerRS232 USB adapter as optionDisplayLCD graphic with backlightMenu available in French, English, Spanish, German, PortuguesePower supplyMains adapter 100-240 VAC (0,4 A/47-63 Hz)BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se6ElectrodesMaintenanceElectrodeVisually inspect the electrode. If there are bubbles in the bottom of the electrode, spin the electrode around by holding the cord. This will push the liquid into the lower part of the electrode rod.Control the crystal level in the electrode. If too high: liquid in the electrode should be emptied, the crystals rinsed with distilled water and the electrode refilled with fresh KCl solution. If too low: fill with saturated KCl or fresh KCl crystals.Clean the electrode regularly with Renovo N (Renovo x if fat samples are measured). To ensure accurate results avoid contact with the bottom of the cup during measurement. Keep the electrode in pH 4 buffer overnight (not colored). Please note that this will lead to higher dissolving of the crystals.Rinse electrode with distilled water between samples. If an electrode is stored in KCl (new electrode), it must be soaked in buffer pH 4 for at least 2 hours before use. Check the electrodes instructions as storage and activation recommendations may differ between electrodes.Conductivity CellClean platinum-coated conductivity cells gently, aggressive cleaning may lead to degradation of the platinum surface layer.Rinse the cell with deionized water between sample measurements. If fat samples have been measured, the cell can first be cleaned with solvents that dissolve the sample (for example ethanol and acetone). Finish by washing the cell with water.If deposits occur on the cell surface, it can be dipped in Renovo N (cleaning kit from Radiometer) for 1h and then be cleaned with deionized water.For short-term storage, the cell can be stored in deionized water. For long-term storage, the cell can be kept dry, or placed in deionized water. After long-term storage, the electrode needs to be placed in deionized water for 8 hours before use.Do not touch the shiny surface of the platinum-coated cells. To clean the platinum cells, dip the cell in deionized water several times. Do not rinse it with excessive water pressure. The pressure may lead to a part of the platinum layer being rinsed off, this will affect the cell-constant and lead to incorrect measurement results.MAINTENANCEBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se7Radiometer Analyticals unique Red Rod Technology providesnot only fast response time but also long-term accuracy andreproducibility.Red Rod ElectrodesRadiometer Analytical - Hach LangeFeatures:Reproducible measuring conditions ensured by the special bayonet head. The electrode fits into place in one easy movement and is fixed safely and securely in the same position for every measurement.Wide temperature range (0 to 100C) thanks to fast temperature response of Red Rod Technology.Trouble-free liquid junction as Red Rod encapsulation of reference elements means no silver ions and therefore less risk of clogging.Fast and accurate response thanks to the symmetrical electrode chain formed by the internal and external Red Rod reference elements.Stable signal as the Red Rod Technology protects the reference elements from light interference. Saturated KCI salt-bridge aids stable liquid junction potential.The symmetry of Red Rod electrodes means that the iso pH is the same as the zero pH which provides highly reproducible results even when temperature fluctuations occur. The figure compares the measurements performed with a general-purpose Red Rod electrode and a traditional combined electrode. A MeterLab setup was used to measure certified standard pH solutions, pH 7.000 thermostated at 50C and pH 4.005 thermostated at 25C. The figure shows the fast response of the Red Rod electrode to changes in pH and temperature (curves offset to increase readability).ELECTRODES Your guarantee of reproducible resultsRed Rod combined pH electrode compared to traditional combined pH electrode6,86,35,85,34,84,33,80 10 20 30 40 50 60 70pHTime (minutes)TraditionaltechnologyRed Rod technologyBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se8The Right Electrode for your ApplicationCombined pH electrodesELECTRODES There is a Radiometer Analytical electrode for every application. The above table gives examples of the many applications for which Radiometer Analytical electrodes can be used. Where possible, choose an electrode which is Recommended but where one electrode is required for several applications, it may be necessary to select one which is Acceptable.Full specifications of the electrodes featuredin the table are given on the following pages.In addition to your application, there are other considerations when choosing an electrode. The length and diameter obviously depend on the sample size and Applications PHC2001pHC2002pHC2003pHC2005pHC2011pHC2015pHC2051pHC2085pHC2401pHC2441pHC2501pHC2601pHC2701pHC3001pHC3005pHC3006pHC3006LpHC3011Alkaline solutionsAqueous solutionsBloodEducation purposesEmulsionsFat/cream/cosmeticsField useGel electrodeHops/beerHydrofluoric acidLacquerLiqueur etc.Long length >150 mmLow ionic strengthMicrosamplesMilkNon-aqueous mediaOilPaintPaperPenetration (cheese)Photo bathsSea water, swimming poolsSoilSolids, high content ofSuspensionsTemperature, high or varyingTemperature sensor, built-inTRIS bufferViscosity, highVoltammetryYogurt, curdled milksample vessel. Radiometer Analytical offers electrodes with various lengths for specialist applications and small diameters for microsamples.Risk of damageAcceptableRecommended Not RecommendedBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se9Combined pH electrodes Reference electrodesGlass electrodesWhen measuring at high temperatures, theelectrochemical system within the electrode needs to be considered. Radiometer Analytical offers Ag/AgCl electrodes specially designed for high temperaturemeasurements.To avoid chloride interference, a referenceELECTRODES electrode with a chloride-free reference system must be used (e.g. Hg/Hg2SO4 with K2SO4 salt-bridge) or a reference electrode with a double salt-bridge construction. Applications pHC3031pHC3081pHC3105pHC3131pHC3359XC161PHG200pHG201pHG211pHG301pHG311XG250REF200REF201REF251REF321REF361XR820Alkaline solutionsAqueous solutionsBloodEducation purposesEmulsionsFat/cream/cosmeticsField useGel electrodeHops/beerHydrofluoric acidLacquerLiqueur etc.Long length >150 mmLow ionic strengthMicrosamplesMilkNon-aqueous mediaOilPaintPaperPenetration (cheese)Photo bathsSea water, swimming poolsSoilSolids, high content ofSuspensionsTemperature, high or varyingTemperature sensor, built-inTRIS bufferViscosity, highVoltammetryYogurt, curdled milkRisk of damageAcceptableRecommended Not RecommendedBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se10To meet your analysis needs, combined pH electrodes are available with a variety of lengths, diameters and reference systems.All our electrodes are delivered with a Certificate of Conformity signed by the Total Quality Manager. This specifies the sensitivity,zero pH, response time and batch number of the electrode.You may need a cable or plug adapter to connect your chosen electrode to your meter.Combined pH ElectrodesRadiometer Analytical - Hach LangeELECTRODES Temperature SensorsType T101 T201 T202 T203Part no. E51M003 E51M001 E51M002 E51M008 Temperature range -10 105C -10 105C -10 105C -10 -105C Diameter (mm) 7.5 7.5 7.5 7.5 mm Material Glass Glass Glass Glass Connection PYE Cinch Cinch RJ9InstrumentPHM83/85ION83/85CDM83PHM2XXCDM2XXPHM9XPHM2XXCDM2XXPHM9XSensION+For pH measurements and measurements with ion-selective electrodes and conductivity cells, use of a temperature sensor is recommended because temperature affects the results.BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se11Radiometer pH ElectrodesApplications General purpose Alkaline samples Model pHC2001 pHC2002 pHC2003 pHC2401 pHC2005 pHC2085 pHC2011 pHC2015 Probe part no. BNC E16M313 E16M315 E16M334 E16M400 E16M500 E16M345 E16M317 E16M318 Probe part no. Type 7 E16M336 E16M337Combination probe YES YES YES YES YES YES YES YES Reference system Red Rod Red Rod Red Rod Red Rod Red Rod Red Rod Red Rod Red Rod Liquid junction Porous pin Porous pin Porous pin Annular ring Porous pin Porous pin Porous pin Porous pin pH range 0 12 0 -12 0 -12 0 -12 0 -12 0 -12 0 -14 0 -14 Temperature included NO NO NO NO NO YES NO NO Temperature range -10 -100C -10 -100C -10 -100C -10 -100C -10 -100C -10 -100C 0 -100C 0 -100C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Minimum sample depth 18 mm 18 mm 18 mm 14 mm 14 mm 14 mm 18 mm 14 mm Special features Long Long Robust Temp. sensor Robust Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibilityApplications Surface measurement Soils Cl-sensitive samples Viscous samples High KCl flow General purpose Model pHC2441 pHC2051 pHC2501 pHC2601 pHC2701 pHC3001 pHC3081 Probe part no. BNC E16M320 E16M319 E16M321 E16M322 E16M323 E16M300 E16M301* E16M344 Probe part no. Type 7 E16M339Combination probe YES YES YES YES YES YES YES Reference system Red Rod Red Rod Red Rod Red Rod Red Rod Ag/AgCl Ag/AgCl Liquid junction Annular ring Porous pin Double/Porous Sleeve Annular ring Porous pin Porous pin pH range 0 -12 0 12 0 -12 0 -12 0 -12 0 -12 0 -12 Temperature included NO NO NO NO NO NO YES Temperature range -10 -100C -10 -100C -10 -100C -10 -100C -10 -100C 0 -80C 0 -80C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Minimum sample depth flat 18 mm 18 mm 18 mm 14 mm 18 mm 18 mm Special features Temp. sensor Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl 3 M KCl + sat. AgCl BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se12Radiometer pH ElectrodesApplications General purposeGeneral purpose General purposeAlkaline samples Alkaline samplesGeneral purposeModel pHC3006 pHC3006L pHC3005 pHC3011 GK2401B GK2401CProbe part no. BNC E16M306* E16M307* E16M302BNC E16M303* E16M324* Probe part no. Type 7 945-261 945-252Combination probe YES YES YES YES YES YESReference system Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Red Rod Red RodLiquid junction Porous pin Porous pin Porous pin Porous pin Porous pin Porous pinpH range 0 -12 0 - 12 0 - 12 0 - 14 0 - 14 0 - 14Temperature range 0 - 80C 0 - 80C 0 - 80C 0 - 80C 0 - 100C -10 - 100CLower diameter 6.5 mm 6.5 mm 12 mm 12 mm 9,5 mm 9,5 mmMinimum sample depth 14 mm 14 mm 12 mm 18 mm 16 mm 16 mmSpecial features Small Long, small Robust Salt-bridge solution 3 M KCl + sat. AgCl 3 M KCl + sat. AgCl 3 M KCl + sat. AgCl 3 M KCl + sat. AgCl Sat. KCl Sat. KClApplications Microsamples Microsamples General-purpose Gel-filledPenetration Gelfilled Penetration Model XC161 pHC3359 pHC3105 pHC3131 pHC3031 Probe part no. B10C161* E16M343BNC E16M308* E16M328* E16M325*Combination probe YES YES YES YES YES Reference system Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Liquid junction Porous pin Fibre Opening Opening Porous pin pH range 0 - 12 0 - 12 2 - 12 2 - 12 0 - 12 Temperature included NO NO NO NO NO Temperature range 0 - 80C 0 - 80C 0 - 80C 0 - 80C 0 - 80CLower diameter 5 mm 3 mm 12 mm 8 mm 8 mm Minimum sample depth 8 mm 2 mm 18 mm 14 mm 14 mm Special features Robust Salt-bridge solution 3 M KCl + sat. AgCl 3 M KCl + sat. AgCl Solid gel (3 M KCl) Solid gel (3 M KCl) 3 M KCl + sat. AgCl ELECTRODES *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibilityBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se13Single and combined metal electrodes can be used for redox measurements, redox titrations or potentiometric techniques hereas double metal electrodes are ideal for imposed current potentiometric titration. Radiometer Analyticals electrode range features single, double and combined metal electrodes with latinum, silver, gold, antimony and glassy carbon sensing elements. Metal and Combined Metal ElectrodesRadiometer Analytical - Hach LangeELECTRODES Metal Electrodes and Combined Metal ElectrodesApplications General- purpose Karl Fischer titrations Redox meas.Silver halides Titra-tionpH meas. titrationRedox meas.Type M241Pt M231Pt M231Pt2 MC3051Pt M295Ag M291Ag MC2095Sb MC201Au-8Part no. E31M001 E31M002* E32M001 E31M003* E34M003 E34M002* E36M001 E36M005Sensing element Platinum plate 5 x 5 mmPlatinum wire 1 mm2 platinum wires 1 mm Platinum ring Silver rod Silver rodAntimony rodGold wire 1 mmTemperature range -10 100C -10 100C -10 100C 0 80C -10 100C 0 80C 0 60C -10 100CLower diameter 7.5 mm 8 mm 12 mm 12 mm 7.5 mm 8 mm 12 mm 12 mmReference system Ag/AgCl Hg/Hg2SO4 Red RodLiquid junction Porous pin Porous pin Porous pinConnection Banana plug Screw cap 2 x banana Screw cap Banana plug Screw cap BNC plug BNC plugSalt-bridge solution 3 M KCl with sat. AgCl Sat. K2SO4 Sat. KClMinimum sample depth 18 mm 18 mm 18 mm 14 mm 18 mm 14 mm Special features Long Long Robust Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Sat. KCl Recommended Reference Electrode *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibilityApplications Voltammetry Voltammetry RedoxType XM110 XM120 XM140 XM150 M291CPart no. B35M110* B35M120* B35M140* B35M150* E36M003*Sensing element Platinum wire 1 mmPlatinum plate 5 x 5 mmPlatinum plate 8 x 8 mmPlatinum disc 10 mmGlassy carbon rod 3 mmTemperature range -10 100C -10 100C -10 100C -10 100C 0 60CDiameter 8 mm 8 mm 8 mm 12 mm 8 mmConnection Screw cap Screw cap Screw cap Screw cap Screw capBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se14pH glass electrodes from Radiometer Analytical are made with highly shock-resistant glass, making them extremely tough. The average lifetime of a correctly maintained glass pH electrode is approximately 2 years.Certain electrodes are made with special glass for pH measurements in strongly alkaline solutions. These electrodes allow measurements within the 0 - 14 pH range without significant deviation from the theoretical response.Glass pH electrodes are always used in combination with reference electrodes. The zero pH of Red Rod glass pH electrodes when used with their recommended reference electrode is approximately pH 6.65. The zero pH of glass pH electrodes is approximately pH 6.65 when measured against a calomel reference electrode (e.g. REF421, XR110) and approximately pH 7.25 when measured against an Ag/AgCl reference electrode (e.g. REF321).Glass pH ElectrodesRadiometer AnalyticalGlass pH electrodesELECTRODES Applications Microsamples General-purpose Alkaline samples General purpose Alkaline samples Alkaline samplesModel pHG200 pHG201 pHG211 pHG301 pHG311 XG250Probe part no. E11M002BNC E11M006BNC E11M003BNC E11M001* E11M004* B10B250*Combination probe NO NO NO NO NO NOReference system Red Rod Red Rod Red Rod Ag/AgCl Ag/AgCl Ag/AgClLiquid junction pH range 0 - 12 0 - 12 0 - 14 0 - 12 0 - 14 0 - 14Temperature included NO NO NO NO NO NOTemperature range 10 - 100C -10 - 100C 10 - 100C 0 - 80C 0 - 80C 0 - 80CLower diameter 4 mm 7.5 mm 7.5 mm 12 mm 12 mm 10 mm**Minimum sample depth 4 mm 7 mm 7 mm 12 mm 12 mm 12 mmSpecial features Salt-bridge solution Recommended Reference Electrode REF200 REF201/251 REF201 for general useREF201/251 REF201 forgeneral use REF321 REF321BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se15During measurement, the salt-bridge junction (also called liquid junction protection tube) prevents the reference electrode from being contaminated by the media and vice-versa. It consists of a glass tube terminated by a liquid junction. Always ensure the filling solution used corresponds to the application.A reference electrode provides a stable potential whatever the measurement conditions. The main differences between reference electrodes are the type of reference system and the liquid junction. Radiometer Analytical offers electrodes using both Red Rod and traditional technology.Electrodes with a double junction are mostly designed for measurements using ion-selective electrodes or samples sensitive to Cl- or K+. Sleeve junctions have a high flow to prevent the risk of clogging. Porous pins are used for general applications. Fibre reference electrodes have a slow flow to avoid contamination of the media.Reference ElectrodesRadiometer AnalyticalSalt-bridge junctionsReference Electrodes*Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibilityApplications Micro-samples General purpose General purpose General purpose Non-aqueous media Voltammetry Impedance Model REF200 REF201 REF251 REF321 REF361 XR300 XR820 Probe part no. E21M008 E21M009 E21M001 E21M002* E21M003 B20B300* B20C820* Reference system Red Rod Red Rod Red Rod Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Liquid junction Porous pin Porous pin Porous pin / porous pin Porous pin Glass sleeve Porous pin Porous pin / fibre Temperature range -10 -100C -10 -100C -10 -100C -5 -80C -5 -80C -5 -80C -5 -80C Lower diameter 4 mm 7.5 mm 12 mm 8 mm 12 mm 8 mm 8 mm Special features For use with pHG200 Double junction Salt-bridge solution Sat. KCl Sat. KCl Sat. KCl 3 M KCl with sat. AgCl 3 M KCl with sat. AgCl Sat. KCl + sat. AgCl Sat. KCl + sat. AgCl upper res. ELECTRODES Type AL100 AL110 AL120Part no. B40A520 B40A550 B40A610Lower diameter 12 mm 8 mm 8 mmJunction Ceramic Ceramic CeramicSpecial features for 7.5 or 8 mm ref. electrodesfor ref. electrodes with ground jointBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se16The use of ion-selective electrodes constitutes a quick and cost-effective method of determining ionic activity.Due to their quality and diversity, Radiometer Analytical ion-selective electrodes efficiently solve various analytical problems of species in solution.Each electrode is carefully checked before packing and is delivered with an individual control report including information such as the response curve, checkpoint value and slope.Ion-selective ElectrodesRadiometer Analytical - Hach LangeELECTRODES Ion-selective ElectrodesIon Species Br - Ca ++ Cl - Cl - CN - Cu ++ F -Model ISE25Br ISE25Ca ISE25Cl ISE/HS25Cl ISE25CN ISE25Cu ISE25F Probe part no. E41M001* E41M002* E41M003* E41M004* E41M005* E41M006* E41M007*Combination probe Concentration range (M) 10 -6 -100 2 x 10 -6 -100 5 x 10 -5 -100 10 -6 -100 5 x 10 -7 -10 -3 10 -6 -100 5 x 10 -7 -100 Concentration range (ppm) 0.08 -80000 0.1 -40000 1.8 -35000 0.04 -35000 0.013 -25 0.06 -60000 0.01 -20000 Temperature range 0 -60C 0 -50C 0 -60C 0 -60C 0 -60C 0 -60C 0 -60C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 7 mm pH range 2 -14 4 -12 2 -14 2 -4 9 -14 0 -14 5 -11 Sensor type Solid-state PVC membrane Solid-state Solid-state Solid-state Solid-state Solid-state Interfering ions I -, S2-, CN -, SCN Zn2+, Pb2+ I -, CN -, Br -, SCN I -, CN -, Br -, SCN I -, Br -, S2 HgS, Ag+, Cl OH Recommended reference electrodes REF251 REF201 REF251 REF251 REF251 REF201 REF251 REF201 REF251 REF201 REF251 *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibilityBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se17Ion-selective ElectrodesIon Species F - I - K+ Na+ NH4 + NO3 - Pb++ Model ISEC301F ISE25I ISE25K ISE21Na ISE25NH4 ISE25NO3 ISE25Pb Probe part no. E41M017* E41M008* E41M009* E41M010* E41M013* E41M014* E41M015* Combination probe Concentration range (M) 5 x 10 -7 -100 10 -6 -10 -1 2 x 10 -6 -100 2 x 10 -6 -100 3 x 10 -6 -100 3 x 10 -6 -100 10 -6 -100 Concentration range (ppm) 0.01 -20000 0.13 -13000 0.08 -40000 0.04 -20000 0.06 -20000 0.2 -60000 0.2 -200000 Temperature range 0 -50C 0 -60C 0 -50C 0 -70C 0 -50C 0 -50C 0 -60C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm pH range 5 -7 2 -12 2 -12 5 -12 3 -8 3 -10 3 -7 Sensor type Solid-state Solid-state PVC membrane Glass PVC membrane PVC membrane Solid-state Interfering ions OH CN -, Hg2+, Br -, SCN NH4 +, Rb+ Li+, NH4 +, Rb+, Ag+ K+ Cl -, Br -, NO2 -Hg2+, Cu2+, Ag+ Recommended reference electrodes REF201 REF251 REF201 REF251 REF251 REF251 REF201 REF251 REF251 *Screw cap electrode. Requires CL114 connection cable (part no. A94L114) for sensION+ meter compatibilityELECTRODES BergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se18It is important to choose a cell with the right construction and geometry for your particular application and working conditions.Radiometer Analytical offers conductivity cells for a wide variety of applications.2-pole cells have a traditional design based on two plates of platinum. They are ideal for routine measurement of conductivity and for use with a sample changer due to the easy rinsing. 3-pole cells consist of 3 platinum rings which facilitate optimal shielding during measurement.Conductivity CellsRadiometer AnalyticalELECTRODES Conductivity Cells Applications General purpose General purpose General purpose General purpose General purpose Sample changer Resistant media Viscous Titration Model CDC536T CDC836T CDC641T CDC745-9 XE100 CDC741T CDC267-9 CDC241-9 Probe part no. RJ45 E61M021 E61M020 E61M022 E61M013* B60E100* E61M023 E61M011* E61M008* Probe part no. MAB6 B15B001 E61M012Body material Epoxy1 Epoxy1 Glass Epoxy Glass Glass Glass Glass Cell constant (cm-1) 1.0 1.0 0.85 1.0 1.0 1.0 0.1 1.0 Number of poles 3 3 2 2 2 2 2 2Platinised NO YES YES YES YES YES NO NO Temperature included YES YES YES NO NO YES NO NO Max. temperature 80C 80C 100C 100C 100C 100C 100C 100C Diameter 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Minimum sample depth 35 mm 35 mm 14 mm 14 mm 10 mm 10 mm 26 mm 10 mm *Screw cap electrode. Requires CL143connection cable (part no. A94L143) for sensION+ meter compatibility1) removable epoxy tube for easy rinsing (can be replaced by glass tube)Conductivity measurement is temperature dependent (if the temperature increases so does the conductivity value). When performing conductivity measurements, it is advisable to choose a cell with a built-in temperature sensor or use a separate sensor.Remember to calibrate your conductivity cell regularly as the cell constant may vary due to changes in electrode surface due to contamination, for example.Some tipsBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se19Recommended conductivity cells by applicationApplications/Characteristics CDC566TCDC866TCDC565CDC641TCDC745-9XE100CDC511TCDC741TCDC861TCDC267-9CDC241-9CDC749Wide conductivity range (general purpose) x x x xVarious aqueous and non-aqueous media x x xVery strong acids and bases xUse with sample changer xBuilt-in temperature sensor x x x x x xContinuous measurements x x xMicrosamples xFlow measurements xTitration xSalinity (high conductivity) x xPure water xMeets requirements of USP 24-NF19 x xMeets requirements of EP 2.2.38 xUse in glass tubes xPlastic body x x x x xViscous media xHighly resistant media xField use x x x xConductivity Cells Applications GeneralpurposeGeneralpurposeGeneralpurposeGeneralpurpose Pure WaterStrong acid basisMicrosamplesType CDC566T CDC866T CDC565 CDC745-9 CDC511T CDC861T CDC749Part no. MAB6 E61M010 E61M015 E61M003 E61M009 E61M016 E61M014Part no. screw cap E61M013Body Epoxy1) Epoxy1) Epoxy Epoxy TPX2) Glass GlassCell. Constant (cm-1) 3) 1.0 1.0 1.0 1.0 1.0 1.0 1.7Number of poles 4 4 4 2 4 4 2Platinised NO YES NO YES NO YES YESTemperature sensor YES YES NO NO YES YES NODiameter (mm) 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm 4 mmMax. temperature 80C 80C 80C 100C 80C 100C 100CMin. immersion depth 35 mm 35 mm 30 mm 14 mm 3 ml4) 35 mm 4 mmCDM210/CDM230 YES YES YES YES3) YES YES YES1) Removable epoxy tube for easy rinsing(can be replaced by glass tube - see accessories)2) Polymethylpentene. Removable part for easy rinsingELECTRODES 3) The cell constant is determined experimentally for each cell and the value is given as a guideline only4) Minimum sample volumeBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se20The use of standards manufactured by an accredited laboratory gives you complete confidence in the traceability chain and calculated uncertainties. Radiometer Analytical is part of the Hach Lange group whose Calibration Laboratory, located in Berlin, is accredited for the calibration of certified pH and conductivitystandards by DKD, the German national accreditation authority. This accreditation (No. DKD-K-47901) is recognised in more than 35 countries. All standards are formulated in compliance with NIST,IUPAC and DIN19266 specifications (1 p. 21).IUPAC Series certified pH standards are fully traceable to the Standard Hydrogen Electrode through Certified Reference Material produced by the Primary Laboratory of either NIST or DFM (2 p. 21). Radiometer Analytical certified conductivity standards are fully traceable to SI units via Certified Reference Materials manufactured by NIST. They are prepared and calibrated according to the internationally recognised demal scale laid down by the International Organisation of Legal Metrology (OIML Recommendation No. 56).Accredited Calibration LaboratoryCERTIFIED STANDARDS** The NaCl 25 certified conductivity standard comes in a 250 ml glass bottle.Radiometer Analytical certified standards are fully traceable. Certificates are always included with the buffer solutions.Type Value Qty Part No.KCl 1D 111.3 mS/cm 0.5% at 25C 500 ml S51M001KCl 0.1D 12.85 mS/cm 0.35% at 25C 500 ml S51M002KCl 0.01D 1408 S/cm 0.5% at 25C 500 ml S51M003NaCl 0.05% 1015 S/cm 0.5% at 25C 500 ml S51M004NaCl 25 25.0 S/cm 5% at 25C 250 ml S51M013**Certified conductivity standardsType Qty Part No.pH4.01 250 ml LZW9463.99pH7.00 250 ml LZW9464.98pH10.00 250 ml LZW9471.99Buffers for certified sensION+* Radiometer Analytical formulation.Type Value Qty Part No.pH1.679 pH 1.679 0.010 at 25C 500 ml S11M001pH4.005 pH 4.005 0.010 at 25C 500 ml S11M002pH6.865 pH 6.865 0.010 at 25C 500 ml S11M003pH7.000* pH 7.000 0.010 at 25C 500 ml S11M004pH7.413 pH 7.413 0.010 at 25C 500 ml S11M005pH9.180 pH 9.180 0.010 at 25C 500 ml S11M006pH10.012 pH 10.012 0.010 at 25C 500 ml S11M007pH12.45 pH 12.45 0.05 at 25C 500 ml S11M008IUPAC Series certified pH standardsType Value Qty Part No.pH4.00 pH 4.00 at 25C 500 ml S11M012pH7.00 pH 7.00 at 25C 500 ml S11M013pH10.00 pH 10.00 at 25C 500 ml S11M0144-7-10 Series ABBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se21Totally reliable packagingEach standard is delivered in an airtight can and is supplied with a film-wrapped Certificate of Conformityand Traceability as well as a DKD Calibration Certificate specifying the exact measured value and calculated expanded uncertainty (k=2) for each batch of pH and conductivity solution.(1) Except pH7.000 formulated by us according to NIST, IUPAC and DIN19266 specifications of pH6.865 and pH7.413.(2) Dansk Fundamental Metrologi A/S is accredited for pH measurements by the Danish Accreditation and Metrology Fund (DANAK) (no. 255).(3) 4-year guarantee for pH standards (2 years for pH 12.45). 2-year guarantee for conductivity standards (1 year for the 25 S/cm). The guarantee is valid from the date of the Certificate of Conformity and Traceability and only applies to standards kept unopened in the sealed can in compliance with the storage recommendations specified in the certificate.Safe storagethanks to the airtight can.BInternational accreditationa DKD Calibration Certificate proves the traceability to national standards.GLP - right from the startthe date of opening can be marked directly on the bottle.Recommended shelf lifethe observed typical shelf life after opening is printed on the bottle, ensuring timely use(2-3 months depending on the standards).A guaranteed valuethe nominal value of the standard is guaranteed until first opening, even after several years storage(3).GLP - every daythe number of uses can be marked directly on the bottle in line with Good Laboratory Practice.A useful referencea pH or conductivity temperature dependence table is printed on the bottle.AProven traceabilityeach standard comes with its own Certificate of Conformity and Traceability.Accurate valuesthe nominal value and the tolerance of pH standards are given with a resolution of 3 significant decimals.Glossary & useful linksNIST National Institute of Standards and Technology www.nist.govIUPAC International Union of Pure and Applied Chemistry www.iupac.orgDFM Danish National Metrology Institute www.dfm.dtu.dkDKD Deutscher Kalibrierdienst www.dkd.euDANAK Danish Accreditation and Metrology Fund www.danak.orgOIML International Organisation of Legal Metrology www.oiml.orgPACKAGINGBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se22Electrode MaintenanceMAINTENANCE Reference element SolutionsRed Rod KClL and KClC KS100 and KClCAg/AgCl (pHC3xxx /REF3xx) KClAgAg/AgCl (XCxxx/ XRxxx) KS120Calomel KClL and KClC KS100 and KClCHg/Hg2SO4 KS160Type Description Qty Part No.RENOVON Normal Cleaning Solution 250 ml S16M001RENOVOX Xtra Strong Cleaning Solution 250 ml S16M002KS400 Pepsin in HCl Solution 250 ml C20C370KS410 Thiourea Solution 250 ml C20C380Type Description Qty Part No.KS100 Saturated KCl Solution 500 ml C20C300KClL Saturated Solution of KCl 100 ml S21M002KClL-30 Saturated Solution of KCl, 30 ml S21M010KClC KCl Crystals 15 g S21M001KClAg 3 M KCl Solution Saturated with AgCl 100 ml S21M004KClAg-30 3 M KCl Solution Saturated with AgCl 30 ml S21M011KS110 KCl Solution 3 M 500 ml C20C320KS120 Saturated KCl + AgCl Solution 500 ml C20C310KS120-30 Saturated KCl + AgCl Solution 30 ml S21M009KS160 Saturated K2SO4 Solution 500 ml C20C500KS160-30 Saturated K2SO4 Solution 30 ml S21M007LiCl-30 1 M LiCl Solution 30 ml S21M008Selecting the right filling solutionMaintenance solutionsFilling and storage solutions forcombined and reference electrodesThe maintenance requirements of electrodes vary according to the application. After measurements in aqueous solutions, cleaning with a mild solution such as RENOVON is sufficient. However, when the solutions contain protein, for example, stronger cleaning agents such as RENOVOX or Pepsin in HCl are required. For junctions contaminated with sulphides or AgCl precipitate, Radiometer Analyticals Thiourea Solution is ideal. The operating instructions provide cleaning instructions for each type of electrode.Maintenance solutionsBergmanLabora AB Box 705 182 17 Danderyd Tel: 08-625 18 50 Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.se23Electrode plug Instrument socket Part no.BNC Type 7 A94P800Type 7 BNC A94P8022 x banana BNC A94P801BNC DIN A94P806BNC Banana A94P807Banana 4 mmBanana US 2 mm X41V001Banana 4 mm Type 7 809-147UHF MAB6 A94P001MAB6 UHF+PYE A94P002Plug adaptersfor screw cap electrodesInstrument socket Type Part no.Banana CL111 A94L111P2 CL112 A94L112DIN CL113 A94L113BNC CL114 A94L114Type 7 CL116 A94L116UHF (PL259) CL119 A94L1192 x banana CL120 A94L120LEMO 5 mm CL129 A94L129MAB6 CL136 A94L136Connection cablesfor screw cap electrodesAccessoriesACCESSORIES KONTAKTA OSS!AnalysinstrumentApparaterFrbrukning labRenrumsprodukterMikroskopi / Optisk mtning ServiceBergmanLabora ABTel: 08-625 18 50Fax: 08-625 18 70 info@bergmanlabora.se www.bergmanlabora.seBL-LIAS-1206 -1

Recommended

View more >